{"id":812,"date":"2026-11-12T15:12:11","date_gmt":"2026-11-12T07:12:11","guid":{"rendered":"http:\/\/www.shestartsafrica.com\/blog\/?p=812"},"modified":"2026-11-12T15:12:11","modified_gmt":"2026-11-12T07:12:11","slug":"how-do-i-reset-an-allen-bradley-plc-4e1c-baa467","status":"publish","type":"post","link":"http:\/\/www.shestartsafrica.com\/blog\/2026\/11\/12\/how-do-i-reset-an-allen-bradley-plc-4e1c-baa467\/","title":{"rendered":"How do I reset an Allen-Bradley PLC?"},"content":{"rendered":"<p>Hey folks, let\u2019s cut to the chase\u2014if you\u2019re here, you\u2019re probably staring at an Allen-Bradley PLC that\u2019s glitching like a old flip phone, or you need a fresh start for a new line build, and you\u2019re wondering: how the heck do I reset this thing? As someone who\u2019s been selling and supporting Allen-Bradley gear for over a decade, I\u2019ve walked more shop floors than I can count where this exact question has saved the day, and I\u2019m here to break it down like I\u2019m talking to a fellow tech, not a textbook. No stuffy jargon, no skipped steps\u2014just the real deal, straight from the supplier who knows these units inside and out. <a href=\"https:\/\/www.autelectrical.com\/allen-bradley\/\">Allen-Bradley<\/a><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.autelectrical.com\/uploads\/43410\/page\/small\/3na3022-siemens-lv-hrc-fuse-elementcfbf1.jpg\"><\/p>\n<p>First off, let\u2019s get one thing straight: \u201creset\u201d for Allen-Bradley PLCs isn\u2019t a one-size-fits-all button you mash when things go sideways. These bad boys come in so many flavors\u2014Micro800, CompactLogix, ControlLogix, even the older SLC 500s\u2014that your reset method changes hard based on which model you\u2019re dealing with. I\u2019ve seen a new industrial electrician try to hard reset a ControlLogix the same way he reset his old Micro810, and that\u2019s how you end up with a messed up program and a panicked call to my shop at 2 a.m. Let\u2019s avoid that.<\/p>\n<p>Let\u2019s start with the most common ones these days, the Micro800 series\u2014super popular for small to mid-sized machine builds, so I get asked about these nonstop. If you\u2019re dealing with a Micro810, Micro820, or Micro850, there\u2019s two main resets you\u2019ll need: a soft reset (no loss of your program, just a quick reboot) and a factory reset (wipe everything, back to when it shipped). Soft resets are easy. First, make sure your PLC is powered on, but not actively running a critical machine cycle\u2014wait for that batch to finish, or pull power if you can\u2019t wait, though a controlled stop is better. Now, locate the \u201cReset\u201d button on the front of the unit. It\u2019s tiny, usually recessed so it doesn\u2019t get bumped by accident, so you\u2019ll need a paper clip or a small flathead screwdriver. Press and hold that button for 2 to 3 seconds max\u2014count slow to three, let go, and boom, it reboots. That\u2019s it. No lost programs, no changed settings, just like turning your laptop off and back on when it lags.<\/p>\n<p>But if that soft reset doesn\u2019t fix what\u2019s broken\u2014like if the unit\u2019s got a faulty program or you want to sell it or move it to a new job\u2014you need a full factory reset for the Micro800s. This one\u2019s a little trickier, so pay attention. First, back up your program if you still have access to it via Connected Components Workbench (CCW) software\u2014trust me, I\u2019ve had too many customers skip this step and cry about a custom recipe program they spent 6 months writing, so don\u2019t be that guy. Once that\u2019s safe, power off the PLC. Now, hold down the \u201cReset\u201d button while you power the unit back on. Keep holding that button for a solid 10 seconds, no peeking, no releasing early. After 10 seconds, the status lights will flash in a specific pattern\u2014usually the Run, Comm, and Error lights all blink together\u2014meaning the reset is working. Let go, and wait 2 minutes for it to finish. When it boots back up, all user programs and settings are gone, just like it was when it came out of the box. That\u2019s the Micro800 playbook.<\/p>\n<p>Next up, the CompactLogix and ControlLogix lines\u2014these are the workhorses for big manufacturing lines, automotive plants, packaging lines, you name it. Way more powerful, so their reset process is a little different, and way less forgiving if you mess up. First, soft reset these: if you\u2019re in the program via RSLogix 5000 or Studio 5000 (the go-to software for these), it\u2019s easy. Go to the \u201cController\u201d tab, select \u201cController Properties,\u201d then hit \u201cRestart Controller.\u201d That\u2019s a controlled soft reset, no need to mess with physical buttons. If you can\u2019t get into the software (like if the PLC\u2019s locked up and not responding), you can do a physical reset too. Most CompactLogix units have a small reset pinhole on the front, and ControlLogix have one on the power supply module. Hold that button for 3 seconds, just like the Micro800, and it\u2019ll reboot. Simple enough, right?<\/p>\n<p>But here\u2019s the big one for these big boys: factory resets. This is the one you only do when you absolutely have to\u2014like if you\u2019re moving a PLC to a new facility, or the program\u2019s corrupted beyond repair, or you need to wipe it for a new application. Let\u2019s start with CompactLogix, since they\u2019re more common than ControlLogix. First, power off the entire chassis\u2014all modules, not just the controller. Now, locate the \u201cMode\u201d rotary switch on the front of the CompactLogix controller. It\u2019s a little dial that normally sits in \u201cRun\u201d or \u201cProgram\u201d mode, right? Flip it all the way to \u201cRemote\u201d mode. Then, while it\u2019s in Remote mode, power the chassis back on. Wait until all the status lights stabilize\u2014usually 30 seconds, give or take. Then, flip that Mode switch back to \u201cProgram\u201d mode, wait another 10 seconds, then flip it back to \u201cRun.\u201d That\u2019s it? Wait, no\u2014hold on, that\u2019s the old-school way. If you\u2019re using Studio 5000 now, there\u2019s a software method too, and it\u2019s less error-prone. Go back to Controller Properties, look for the \u201cFactory Reset\u201d option, and click it. It\u2019ll walk you through a confirmation, and when it\u2019s done, the controller\u2019s wiped, just like new. But here\u2019s the rule I drum into every customer: always back up your program first. Always. I\u2019ve had so many factory reset disasters where someone forgot that step, and now they\u2019re paying me to write a new program from scratch. Don\u2019t do that.<\/p>\n<p>ControlLogix is similar, but there\u2019s a key difference because they have redundant power supplies and sometimes redundant controllers, so you can\u2019t just flip switches willy-nilly. If you\u2019re doing a factory reset on a non-redundant ControlLogix, it\u2019s almost identical to CompactLogix: power off, flip the Mode switch to Remote, power on, switch back to Program then Run. But for redundant systems, you have to take the secondary controller offline first, reset that, then do the primary, otherwise you\u2019ll end up with a fault that takes the whole line down. I learned that the hard way last year when a customer tried to skip that step and shut down their entire automotive assembly line for 4 hours. Ouch. So take it slow, check the software\u2019s documentation for redundant steps, or just call my team\u2014we\u2019re here for that.<\/p>\n<p>Now, what about the old timers, the SLC 500 series? A lot of facilities still run these, so they don\u2019t just disappear. If you\u2019ve got an SLC 5\/03, 5\/04, or 5\/05, soft reset is easy: just power cycle the unit. Factory reset is a little different too. You\u2019ll need to hold down the \u201cI\/O Clear\u201d button while powering the PLC on, hold for 10 seconds, then release. That\u2019ll wipe all user programs and reset the I\/O configuration to default. Pro tip for SLCs: always check the battery first if it\u2019s acting up\u2014old batteries can corrupt programs, so a replacement might be cheaper than a reset.<\/p>\n<p>Wait a second\u2014before you go mashing any buttons, there\u2019s a few non-negotiables I can\u2019t skip, because they\u2019ve saved more people than I can count. First, label everything. If you\u2019re resetting a PLC that\u2019s part of a custom line, take photos of all the module connections before you touch anything. I\u2019ve had a customer spend an entire weekend re-pinning a CompactLogix chassis because they unplugged modules and forgot where each one went after a reset. Second, never reset a PLC mid-cycle. Wait for the current batch to finish, or trigger a safe stop\u2014you don\u2019t want a conveyor full of parts halfway moving because your PLC rebooted. Third, always back up. Even if you\u2019re 100% sure the program\u2019s on a server, save a local copy too. Servers crash, USB drives get lost, I\u2019ve seen it all.<\/p>\n<p>As your go-to Allen-Bradley supplier, let me also mention a quick cheat code that\u2019s easy to forget: most of these models have built-in diagnostics that can tell you if a reset is even necessary. If your PLC\u2019s throwing error codes like F1 or E1, a quick soft reset might fix it, but if it\u2019s codes like F5 or a persistent communication error, that\u2019s a hardware issue, not a software reset. My team always tells folks: if a soft reset doesn\u2019t do the trick after 2 tries, don\u2019t keep resetting it\u2014call us. We\u2019d rather troubleshoot a hardware fault than have you blow a $500 controller by over-resetting it.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.autelectrical.com\/uploads\/43410\/small\/3bhb027204r0001-3bsm001866-18-power-supplyf4ef6.jpg\"><\/p>\n<p>Now, if you\u2019ve made it this far, you\u2019re either stuck with a glitching PLC, prepping for a new machine build, or just curious how these things work. Whether you need a quick reset tip, a replacement part, or a brand-new Allen-Bradley PLC to update your line, my team\u2019s got your back. We stock all the popular models\u2014Micro800, CompactLogix, even the legacy SLCs\u2014and we don\u2019t sell you stuff you don\u2019t need. No pressure, no hidden fees, just good gear and solid support. If you\u2019re ready to chat through your project, or pick up parts, just reach out. We\u2019re here to help you keep your lines running, no headaches required.<\/p>\n<h3>References<\/h3>\n<p><a href=\"https:\/\/www.autelectrical.com\/siemens\/industrial-drives\/\">Industrial Drives<\/a> Allen-Bradley Micro800 System User Manual, Rockwell Automation.<br \/>\nCompactLogix 5370 Controller User Guide, Rockwell Automation.<br \/>\nSLC 500 Programmable Controllers Instruction Set Manual, Rockwell Automation.<br \/>\nStudio 5000 Logix Designer Help Center, Rockwell Automation.<\/p>\n<hr>\n<p><a href=\"https:\/\/www.autelectrical.com\/\">Xiamen Shengcheng Automation Co., Ltd.<\/a><br \/>As one of the most professional allen-bradley suppliers in China, we offer a wide range of products with superior quality. Please rest assured to buy bulk discount allen-bradley from our factory. For price consultation, contact us.<br \/>Address: Room 1104, Building A, No.1 Golden Bay Fortune Center, No. 999, Anling Road, Heshan Street, Huli District, Xiamen City, Fujian Province, China<br \/>E-mail: sales@cn2014.com<br \/>WebSite: <a href=\"https:\/\/www.autelectrical.com\/\">https:\/\/www.autelectrical.com\/<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Hey folks, let\u2019s cut to the chase\u2014if you\u2019re here, you\u2019re probably staring at an Allen-Bradley PLC &hellip; <a title=\"How do I reset an Allen-Bradley PLC?\" class=\"hm-read-more\" href=\"http:\/\/www.shestartsafrica.com\/blog\/2026\/11\/12\/how-do-i-reset-an-allen-bradley-plc-4e1c-baa467\/\"><span class=\"screen-reader-text\">How do I reset an Allen-Bradley PLC?<\/span>Read more<\/a><\/p>\n","protected":false},"author":425,"featured_media":812,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[775],"class_list":["post-812","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-industry","tag-allen-bradley-43e4-bb467f"],"_links":{"self":[{"href":"http:\/\/www.shestartsafrica.com\/blog\/wp-json\/wp\/v2\/posts\/812","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/www.shestartsafrica.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"http:\/\/www.shestartsafrica.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"http:\/\/www.shestartsafrica.com\/blog\/wp-json\/wp\/v2\/users\/425"}],"replies":[{"embeddable":true,"href":"http:\/\/www.shestartsafrica.com\/blog\/wp-json\/wp\/v2\/comments?post=812"}],"version-history":[{"count":0,"href":"http:\/\/www.shestartsafrica.com\/blog\/wp-json\/wp\/v2\/posts\/812\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/www.shestartsafrica.com\/blog\/wp-json\/wp\/v2\/posts\/812"}],"wp:attachment":[{"href":"http:\/\/www.shestartsafrica.com\/blog\/wp-json\/wp\/v2\/media?parent=812"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/www.shestartsafrica.com\/blog\/wp-json\/wp\/v2\/categories?post=812"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/www.shestartsafrica.com\/blog\/wp-json\/wp\/v2\/tags?post=812"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}